Abstract
Telephone Controlled Switch implies control of devices
at a remote location via circuit interfaced to the remote telephone line/device
by dialing specific DTMF (dual tune multi frequency) digits from a local telephone.
Using this system the user can access any load from a remote location. Each load
will be given a code number. All he has to do is dial the corresponding code through
a local phone. This system can selectively
turn on or off multiple loads one at a time or switch off all the loads simultaneously.
It also provides you feedback when the circuit is in energized state and also
sends an acknowledgement indicating action with respect to the switching on of
each load and switching off of all loads (together). This is a micro controller
aided system where a ring detector, auto lifter and DTMF decoder work together
to place a call and a relay driver connects the required load. This makes the
task of the various operators easy as they can sit anywhere and control the status
of the various loads. In the existing system if an operator in and industry
has to control a certain load there is no other method than being physically present
at the site of the load. If he has to switch off a system after a particular period
he will have to wait till the completion of the operation. But our project titled
"Telephone controlled switch" rectifies this disadvantage of conventional
systems. This system as its name suggests help the user to control the status
of various loads from any remote location through a telephone connection.
As mentioned this system implies control of devices at a remote location via circuit
interfaced to the remote telephone line/device by dialing specific DTMF (dual
tune multi frequency) digits from a local telephone. For this each of the loads
that the operator intends to control is given a code number and is connected to
the telephone line through relay drivers and micro controller. So when the user
dials the respective codes the corresponding loads can be accessed. Then its status
can be controlled using some other code. All this is made possible by programming
the micro controller. This project telephone
controlled load activator has the following features. 1.
It can control multiple load (on/off/status of each load) 2.
It provides you feedback when the circuit is in energized state and also sends
an acknowledgement indicating action with respect to the switching on of each
load and switching off of all loads (together).
.
<<
back |